top of page

Rapidox 6100 C4-FN & C5-FK

The Rapidox 6100 C4-FN & C5-FK is a fully- automatic zero-emissions multi-gas gas analyser for measuring gas compartments containing mixtures of C4-FN (Novec 4710) & C5-FK (Novec 5110) blended with CO2 and O2, all combined in a single portable instrument.

Common brand names for these gases are g3 and AirPlus. The modular design allows the customer to purchase only the gas types they require with the potential to upgrade the instrument in the future. The Rapidox measures the gas purity, water-content and contamination gases for each gas type in high voltage switchgear, circuit breakers and transformers as well as gas bottles. It is a fully portable lithium battery powered instrument.


Exceptional accuracy and stability are provided when measuring the purity of the compartment gas, through specially selected sensors. The modular configuration allows for up to six compatible gases to be analysed simultaneously in each gas type, using one analyser. The Rapidox is fully compatible with mixtures of C4-FN & CO2/O2, C5-FK & CO2, together with carbon monoxide which is the primary toxic contamination gas. The unit also measures the water content of the gas in dewpoint or ppm to ensure dryness is

acceptable.


The Rapidox 6100 C4-FN & C5-FK is housed neatly in an IP66-rated Peli transport case and supplied with sample hoses, DN8 and DN20 coupling accessories. Once powered and connected, the operator can select which gas blend to work with and the Rapidox configures the measurement screen correctly. If the user is changing gas type the unit will run a purge cycle to clean the existing gas from the analyser and into an external recovery bag. During the measurement the Rapidox automatically removes a small quantity of pressurised gas from the electrical equipment or gas cylinder, controlled with an automatic pressure sensing function. A vacuum purge cycle and internal gas storage system ensures that no air can contaminate the gas sample and that no test gas is able to escape during the testing period.

  • Technical Specifications

    Specifications


    Ambient Operating Conditions

    -10°C to +40°C, 10–90% RH, 600–1100mbar

    Warm-up Time

    Min 3–4 minutes at 20°C (Recommended 15 mins to achieve full accuracy)

    Charging Voltage

    90–260 VAC, 50/60Hz

    Battery Life

    Up to 8 hours. 4–6 hour charge

    Sample Connections

    Rectus style fitting compatible with famous brands

    Data Outputs

    Excel compatible data via USB memory stick

    Data Storage

    4GB internal data storage allowing for approximately 1 year of continuous monitoring

    Compressor

    Up to 10 Bar with up to 25 cycles per battery charge at 20°C

    Measurement Time

    2–8 minutes (Min 6 minutes required for H₂O)

    Pressure Range

    0.5–35 Bar

    Gas Flow Rate

    0.5 L.min⁻¹

    Max Inlet Pressure

    35 Bar gauge (10 Bar for Pumpback operation)

    Display

    7" (178mm) full-colour LCD touch screen interface with soft menu keys

    Printer

    Integrated thermal printer allows output of results on demand

    Analyser Dimensions

    270mm(H) x 560mm(W) x 450mm(D)

    Weight

    21kg (Total instrument and case)